محطات معالجة الصرف الصحي بنظام أر بي سي / SEWAGE معدات حماية البيئة


CAPACITY: 500 m3/day up 35000 m3/day
SYSTEM OF TREATMENT:
The company designs installs and constructs
sewage water treatment plants.( Rotary
biological contactors RBC )
WATER SPECIFICATION BEFORE
AND AFTER TREATMENT:
T&S : before 500mg/L - after 50mg/L
BOD : before 500mg/L - after 60mg/L
COD : before 700mg/L - after 80mg/L
according to specifications of WHO
MAIN COMPONENTS:
- pretreatment equipments :
- mechanical and manual screen system
- Grit Sand removal unit
- Biological stage :
- Aeration . Biological treatment basin
- Clorifier / Setting basin - Sludge thicken basin
- Chlorination equipments :
Chlorine contact basin
- Instrumentation and control unit
TECHNICAL SPECIFICATIONS :-
- Electrical power ( installed) :180 kw
- Operation period : 20 hr/day
- Required area : 420 m2
السعات :من ٥٠٠ م ٣ / يوم حتى ٣٥٠٠٠ م ٣/ يوم
نظام المعالجة :
تقوم الشركة بتصميم وانشاء وتركيب محطات معالجة
( RBC ) مياه الصرف الصحي بنظام الأقراص الدوارة
- مواصفات المياه قبل وبعد المعالجة :
المواد العالقة
قبل ٥٠٠ ملجم/لتر - بعد ٥٠ ملجم/لتر
الأكسجين الحيوي المستهلك
قبل ٥٠٠ ملجم/لتر - بعد ٦٠ ملجم/لتر
الأكسجين الكيميائي المستهلك
قبل ٧٠٠ ملجم/لتر - بعد ٨٠ ملجم/لتر
WHO مطابقة للمواصفات القياسية
- المكونات :
- المعالجة المبدئية :
- المصفاة الميكانيكية والمصفاة اليدوية
– وحدة إزالة الرمال
- المعالجة البيولوجية :
- أحواض التهوية والمعالجة البيولوجية
- أحواض الترسيب والتزويق - خزان تركيز الحمأه
– معدات الكلورة : خزان تلامس الكلور
- أجهزة القياس والتحكم
المواصفات الفنية :
- القدرة الكهربائية المركبة : ١٨٠ كيلو / وات
- فترة التشغيل : ٢٠ ساعة / يوم
- المساحة المطلوبة : ٤٢٠ م